{"product_id":"itel-ipv-8k48u-8kw-48v-ip54-hybrid-solar-inverter","title":"iTel IPV-8K48U 8kW 48V IP54 Hybrid Solar Inverter","description":"\u003cdiv class=\"satluj-specifications\"\u003e\n\n\u003ch2\u003eiTel IPV-8K48U 8kW 48V IP54 Hybrid Solar Inverter – Specifications\u003c\/h2\u003e\n\n\u003ctable\u003e\n\n\u003cthead\u003e\n\n\u003ctr\u003e\n\n\u003cth\u003eSpecification\u003c\/th\u003e\n\n\u003cth\u003eDetails\u003c\/th\u003e\n\n\u003c\/tr\u003e\n\n\u003c\/thead\u003e\n\n\u003ctbody\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eBrand\u003c\/td\u003e\n\n\u003ctd\u003eiTel\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eModel\u003c\/td\u003e\n\n\u003ctd\u003eIPV-8K48U\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eInverter Type\u003c\/td\u003e\n\n\u003ctd\u003eHybrid Solar Inverter\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003ePhase\u003c\/td\u003e\n\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eRated Output Power\u003c\/td\u003e\n\n\u003ctd\u003e8kW\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum Output Apparent Power\u003c\/td\u003e\n\n\u003ctd\u003e8kVA\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum Surge Power\u003c\/td\u003e\n\n\u003ctd\u003e16kW @ 5 seconds\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eBattery Voltage\u003c\/td\u003e\n\n\u003ctd\u003e48V DC\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eBattery Voltage Range\u003c\/td\u003e\n\n\u003ctd\u003e40–60V\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\n\u003ctd\u003eLead-acid \/ Lithium-ion \/ User Defined\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum PV Input Power\u003c\/td\u003e\n\n\u003ctd\u003e16,000W\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum PV Voltage\u003c\/td\u003e\n\n\u003ctd\u003e500V DC\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003ePV Start-up Voltage\u003c\/td\u003e\n\n\u003ctd\u003e75V DC\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMPPT Voltage Range\u003c\/td\u003e\n\n\u003ctd\u003e85–450V DC\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum PV Input Current\u003c\/td\u003e\n\n\u003ctd\u003e30A + 15A\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMPPT Trackers\u003c\/td\u003e\n\n\u003ctd\u003e2\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMPPT Tracking Efficiency\u003c\/td\u003e\n\n\u003ctd\u003e≥99.5%\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eBattery Mode Conversion Efficiency\u003c\/td\u003e\n\n\u003ctd\u003e≥93%\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum MPPT Charging Current\u003c\/td\u003e\n\n\u003ctd\u003e160A\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum Mains\/Generator Charging Current\u003c\/td\u003e\n\n\u003ctd\u003e160A\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum Battery Discharge Current\u003c\/td\u003e\n\n\u003ctd\u003e180A\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum Grid Input Voltage\u003c\/td\u003e\n\n\u003ctd\u003e380V\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAC Input Voltage\u003c\/td\u003e\n\n\u003ctd\u003e220V \/ 230V \/ 240V\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAC Input Voltage Range\u003c\/td\u003e\n\n\u003ctd\u003e90–280V AC\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum AC Input Current\u003c\/td\u003e\n\n\u003ctd\u003e36.4A\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAC Output Voltage\u003c\/td\u003e\n\n\u003ctd\u003e220V \/ 230V \/ 240V AC\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\n\u003ctd\u003e50Hz\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eTotal Harmonic Distortion\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;3%\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eUPS Switching Time\u003c\/td\u003e\n\n\u003ctd\u003e10ms\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eAppliance Switching Time\u003c\/td\u003e\n\n\u003ctd\u003e20ms\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eOverload Capacity\u003c\/td\u003e\n\n\u003ctd\u003e105–150% @ 10s; 150–200% @ 5s\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eSmart Load Support\u003c\/td\u003e\n\n\u003ctd\u003eYes\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMain Load Support\u003c\/td\u003e\n\n\u003ctd\u003eYes\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDiesel Generator Support\u003c\/td\u003e\n\n\u003ctd\u003eYes\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\n\u003ctd\u003eWi-Fi \/ RS485 \/ CAN \/ RS232 \/ Dry Contact\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eParallel Operation\u003c\/td\u003e\n\n\u003ctd\u003eUp to 9 units Single Phase \/ 12 units Three Phase\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCooling System\u003c\/td\u003e\n\n\u003ctd\u003eIntelligent Fan Cooling\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\n\u003ctd\u003e\u0026lt;55dB with PV \/ \u0026lt;45dB without PV\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\n\u003ctd\u003e-10°C to +55°C\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eMaximum Operating Altitude\u003c\/td\u003e\n\n\u003ctd\u003e4000m\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\n\u003ctd\u003eIP54\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eProtection Functions\u003c\/td\u003e\n\n\u003ctd\u003eOvervoltage \/ Overload \/ Short Circuit \/ Over Temperature \/ Surge Protection\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eDimensions (D × W × H)\u003c\/td\u003e\n\n\u003ctd\u003e12.5 × 42 × 52 cm\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\n\u003ctd\u003e20 kg\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\n\u003ctd\u003eIEC62109-1 \/ IEC62109-2 \/ IEC61683\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003ctr\u003e\n\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\n\u003ctd\u003e3-Year Replacement\u003c\/td\u003e\n\n\u003c\/tr\u003e\n\n\u003c\/tbody\u003e\n\n\u003c\/table\u003e\n\n\u003c\/div\u003e\n\n\u003cstyle\u003e\n\n.satluj-specifications {\u003cbr \/\u003e    width: 100%;\u003cbr \/\u003e    margin: 20px 0;\u003cbr \/\u003e    font-family: inherit;\u003cbr \/\u003e}\u003c\/p\u003e\n\n\u003cp\u003e.satluj-specifications h2 {\u003cbr \/\u003e    font-size: 28px;\u003cbr \/\u003e    margin-bottom: 22px;\u003cbr \/\u003e    color: #172b4d;\u003cbr \/\u003e}\u003c\/p\u003e\n\n\u003cp\u003e.satluj-specifications table {\u003cbr \/\u003e    width: 100%;\u003cbr \/\u003e    border-collapse: collapse;\u003cbr \/\u003e    font-size: 15px;\u003cbr \/\u003e    background: #fff;\u003cbr \/\u003e}\u003c\/p\u003e\n\n\u003cp\u003e.satluj-specifications th {\u003cbr \/\u003e    background: #f1f3f5;\u003cbr \/\u003e    color: #172b4d;\u003cbr \/\u003e    text-align: left;\u003cbr \/\u003e    font-weight: 600;\u003cbr \/\u003e    padding: 14px;\u003cbr \/\u003e    border: 1px solid #e1e5e9;\u003cbr \/\u003e}\u003c\/p\u003e\n\n\u003cp\u003e.satluj-specifications td {\u003cbr \/\u003e    padding: 13px 14px;\u003cbr \/\u003e    border: 1px solid #e1e5e9;\u003cbr \/\u003e    color: #344054;\u003cbr \/\u003e    vertical-align: top;\u003cbr \/\u003e}\u003c\/p\u003e\n\n\u003cp\u003e.satluj-specifications td:first-child {\u003cbr \/\u003e    width: 45%;\u003cbr \/\u003e    font-weight: 600;\u003cbr \/\u003e    color: #172b4d;\u003cbr \/\u003e}\u003c\/p\u003e\n\n\u003cp\u003e.satluj-specifications tr:nth-child(even) td {\u003cbr \/\u003e    background: #fafbfc;\u003cbr \/\u003e}\u003c\/p\u003e\n\n\u003cp\u003e@media (max-width: 768px) {\u003cbr \/\u003e    .satluj-specifications h2 {\u003cbr \/\u003e        font-size: 22px;\u003cbr \/\u003e    }\u003c\/p\u003e\n\n\u003cp\u003e    .satluj-specifications table {\u003cbr \/\u003e        font-size: 13px;\u003cbr \/\u003e    }\u003c\/p\u003e\n\n\u003cp\u003e    .satluj-specifications th,\u003cbr \/\u003e    .satluj-specifications td {\u003cbr \/\u003e        padding: 10px;\u003cbr \/\u003e    }\u003c\/p\u003e\n\n\u003cp\u003e    .satluj-specifications td:first-child {\u003cbr \/\u003e        width: 42%;\u003cbr \/\u003e    }\u003cbr \/\u003e}\u003cbr \/\u003e\u003c\/style\u003e\n\n\n\n \n\n\u003ch2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"o7obcl\" data-start=\"1125\" data-end=\"1177\"\u003eiTel IPV-8K48U 8kW 48V IP54 Hybrid Solar Inverter\u003c\/h2\u003e\n\n\u003cp data-start=\"1179\" data-end=\"1455\"\u003eThe \u003cstrong data-start=\"1183\" data-end=\"1201\"\u003eiTel IPV-8K48U\u003c\/strong\u003e is a high-capacity \u003cstrong data-start=\"1221\" data-end=\"1263\"\u003e8kW single-phase hybrid solar inverter\u003c\/strong\u003e designed for customers who need strong solar generation, battery backup and flexible energy management for larger homes, agricultural applications, offices and small commercial installations.\u003c\/p\u003e\n\n\u003cp data-start=\"1457\" data-end=\"1786\"\u003eWith a \u003cstrong data-start=\"1464\" data-end=\"1487\"\u003erated output of 8kW\u003c\/strong\u003e and up to \u003cstrong data-start=\"1498\" data-end=\"1532\"\u003e16kW surge power for 5 seconds\u003c\/strong\u003e, the inverter is designed to handle demanding loads and appliances with higher starting requirements. It operates with a \u003cstrong data-start=\"1654\" data-end=\"1676\"\u003e48V battery system\u003c\/strong\u003e and supports \u003cstrong data-start=\"1690\" data-end=\"1747\"\u003elead-acid, lithium-ion and user-defined battery types\u003c\/strong\u003e.\u003c\/p\u003e\n\n\n\n\u003ch3 data-section-id=\"1mc5eqx\" data-start=\"1788\" data-end=\"1817\"\u003eHigh solar input capacity\u003c\/h3\u003e\n\n\u003cp data-start=\"1819\" data-end=\"2102\"\u003eThe IPV-8K48U supports up to \u003cstrong data-start=\"1848\" data-end=\"1871\"\u003e16,000W of PV input\u003c\/strong\u003e and uses \u003cstrong data-start=\"1881\" data-end=\"1902\"\u003etwo MPPT trackers\u003c\/strong\u003e. Its maximum PV voltage is \u003cstrong data-start=\"1930\" data-end=\"1938\"\u003e500V\u003c\/strong\u003e, with an MPPT operating range of \u003cstrong data-start=\"1972\" data-end=\"1984\"\u003e85V–450V\u003c\/strong\u003e. This gives installers considerable flexibility when designing the solar array.\u003c\/p\u003e\n\n\n\n\u003ch3 data-section-id=\"1i6frn8\" data-start=\"2104\" data-end=\"2133\"\u003ePowerful battery charging\u003c\/h3\u003e\n\n\u003cp data-start=\"2135\" data-end=\"2397\"\u003eThe inverter supports up to \u003cstrong data-start=\"2163\" data-end=\"2193\"\u003e160A MPPT charging current\u003c\/strong\u003e, \u003cstrong data-start=\"2195\" data-end=\"2236\"\u003e160A mains\/generator charging current\u003c\/strong\u003e, and up to \u003cstrong data-start=\"2248\" data-end=\"2282\"\u003e180A battery discharge current\u003c\/strong\u003e. This makes it suitable for larger 48V lithium or lead-acid battery systems.\u003c\/p\u003e\n\n\n\n\u003ch3 data-section-id=\"g7jbjy\" data-start=\"2399\" data-end=\"2420\"\u003eDual-load support\u003c\/h3\u003e\n\n\u003cp data-start=\"2422\" data-end=\"2690\"\u003eThe IPV-8K48U supports \u003cstrong data-start=\"2445\" data-end=\"2481\"\u003eMain Load and Smart Load outputs\u003c\/strong\u003e, allowing users to prioritize certain appliances and manage high-power loads more intelligently. It also supports \u003cstrong data-start=\"2596\" data-end=\"2617\"\u003ediesel generators\u003c\/strong\u003e for additional backup flexibility.\u003c\/p\u003e\n\n\n\n\u003ch3 data-section-id=\"1qkzfbx\" data-start=\"2692\" data-end=\"2711\"\u003eIP54 protection\u003c\/h3\u003e\n\n\u003cp data-start=\"2713\" data-end=\"3014\"\u003eThe inverter has an \u003cstrong data-start=\"2733\" data-end=\"2759\"\u003eIP54 protection rating\u003c\/strong\u003e, providing protection against dust and water splashes. This makes it suitable for demanding installation environments while still requiring sensible installation practices and protection from direct weather exposure.\u003c\/p\u003e\n\n\n\n\u003ch3 data-section-id=\"evbqmw\" data-start=\"3016\" data-end=\"3054\"\u003eSmart monitoring and communication\u003c\/h3\u003e\n\n\u003cp data-start=\"3056\" data-end=\"3285\"\u003eBuilt-in communication options include \u003cstrong data-start=\"3095\" data-end=\"3139\"\u003eWi-Fi, RS485, CAN, RS232 and Dry Contact\u003c\/strong\u003e, giving users and installers multiple options for monitoring, battery communication and system integration.\u003c\/p\u003e\n\n\n\n\u003ch3 data-section-id=\"1iz91iu\" data-start=\"3287\" data-end=\"3303\"\u003eKey Features\u003c\/h3\u003e\n\n\u003cul data-start=\"3305\" data-end=\"3853\"\u003e\n\n \t\u003cli data-section-id=\"187njud\" data-start=\"3305\" data-end=\"3327\"\u003e\u003cstrong data-start=\"3307\" data-end=\"3327\"\u003e8kW rated output\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"ekp06y\" data-start=\"3328\" data-end=\"3352\"\u003e\u003cstrong data-start=\"3330\" data-end=\"3352\"\u003e48V battery system\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"13v7kxx\" data-start=\"3353\" data-end=\"3381\"\u003e\u003cstrong data-start=\"3355\" data-end=\"3381\"\u003eSingle-phase operation\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"s9bvvg\" data-start=\"3382\" data-end=\"3412\"\u003e\u003cstrong data-start=\"3384\" data-end=\"3412\"\u003e16,000W maximum PV input\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"4topd9\" data-start=\"3413\" data-end=\"3428\"\u003e\u003cstrong data-start=\"3415\" data-end=\"3428\"\u003eDual MPPT\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"s37dxj\" data-start=\"3429\" data-end=\"3458\"\u003e\u003cstrong data-start=\"3431\" data-end=\"3458\"\u003e500V maximum PV voltage\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"ledlnd\" data-start=\"3459\" data-end=\"3499\"\u003e\u003cstrong data-start=\"3461\" data-end=\"3499\"\u003e160A maximum MPPT charging current\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"yqnno8\" data-start=\"3500\" data-end=\"3544\"\u003e\u003cstrong data-start=\"3502\" data-end=\"3544\"\u003e180A maximum battery discharge current\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"16yhupj\" data-start=\"3545\" data-end=\"3581\"\u003e\u003cstrong data-start=\"3547\" data-end=\"3581\"\u003e16kW surge power for 5 seconds\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"rjcqvl\" data-start=\"3582\" data-end=\"3610\"\u003e\u003cstrong data-start=\"3584\" data-end=\"3610\"\u003eMain Load + Smart Load\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"d0i3ar\" data-start=\"3611\" data-end=\"3632\"\u003e\u003cstrong data-start=\"3613\" data-end=\"3632\"\u003eIP54 protection\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"2gs35k\" data-start=\"3633\" data-end=\"3655\"\u003e\u003cstrong data-start=\"3635\" data-end=\"3655\"\u003eWi-Fi monitoring\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"1918dta\" data-start=\"3656\" data-end=\"3695\"\u003e\u003cstrong data-start=\"3658\" data-end=\"3695\"\u003eRS485 \/ CAN \/ RS232 \/ Dry Contact\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"en4qhy\" data-start=\"3696\" data-end=\"3726\"\u003e\u003cstrong data-start=\"3698\" data-end=\"3726\"\u003eDiesel generator support\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"zxo5ue\" data-start=\"3727\" data-end=\"3751\"\u003e\u003cstrong data-start=\"3729\" data-end=\"3751\"\u003eParallel operation\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"ig57hl\" data-start=\"3752\" data-end=\"3781\"\u003e\u003cstrong data-start=\"3754\" data-end=\"3781\"\u003eIntelligent fan cooling\u003c\/strong\u003e\u003c\/li\u003e\n\n \t\u003cli data-section-id=\"ej99vy\" data-start=\"3782\" data-end=\"3853\"\u003e\u003cstrong data-start=\"3784\" data-end=\"3815\"\u003e3-year replacement warranty\u003c\/strong\u003e\u003c\/li\u003e\n\n\u003c\/ul\u003e\u003ch3\u003eAdditional specifications\u003c\/h3\u003e\u003ctable style=\"width:100%\"\u003e\n\u003ctr\u003e\n\u003cth\u003eBrand\u003c\/th\u003e\n\u003ctd\u003eItel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProduct Type\u003c\/th\u003e\n\u003ctd\u003eHybrid Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRated Power\u003c\/th\u003e\n\u003ctd\u003e8kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Itel","offers":[{"title":"Default Title","offer_id":56241219404148,"sku":"IPV-8K48U","price":205000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1027\/9960\/6132\/files\/itel-4kw-pro_afb9514e-6403-44ac-9ec7-01383c71a091.png?v=1791107161","url":"https:\/\/satlujsolar.com\/products\/itel-ipv-8k48u-8kw-48v-ip54-hybrid-solar-inverter","provider":"Satluj Solar","version":"1.0","type":"link"}